Category Archives: Sas2ircu mptlib2 error 1

Sas2ircu mptlib2 error 1

My HP Ultrium external tape drive is not being detected by the computer at all. I've tried everything I could find with regard to installing drivers, checking compatibility, etc, but to no avail. I appreciate any advice you can provide - many thanks in advance for your help in resolving this issue. And actually:. So I'm really at a loss. I can buy one of those cards too in the hope that it makes a compatibility difference, but I have no real reason to believe it will help.

RH2288H V3 系统侧执行RAID卡命令有报错

In the hope that this might be a compatibility problem. I'll post the results obviously when I've been able to re-test. Some SAS controllers don't and cause errors to be reported when the issue was one that should have been able to be recovered without error.

A few array controllers block out devices that report as tape but I have only seen that with array controllers. The HPE P with cache module card that you list in your later message definitely should work with your tape drive and has been tested with a lot of different HPE tape drives but it is an older controller that isn't tested very often anymore.

Otherwise I don't have a lot of suggestions I can offer at this point. Version All rights reserved. Were you able to solve this issue?

Microwave oven embedded system pdf

Sas controller shows up in device manager windows 10, but no LTO drive recognized in windows. Turn on suggestions. Auto-suggest helps you quickly narrow down your search results by suggesting possible matches as you type.

Ninja selling scripts

Showing results for. Search instead for. Did you mean:. Resources Announcements Email us Feedback. Log In. New Discussion. Occasional Advisor. All forum topics Previous Topic Next Topic. Many thanks, Rob. HPE Pro. I just read through your posting.

Escape from tarkov infinite money 2019

It is an interesting case. The cable you list should also be fine. I work for HPE. Thanks very much for the response Curtis. Really appreciate your thoughts. Thanks again, Rob. New Member. The opinions expressed above are the personal opinions of the authors, not of Hewlett Packard Enterprise. By using this site, you accept the Terms of Use and Rules of Participation. Hewlett Packard Enterprise International.When you use the sas2ircu command within Oracle Solaris to create a RAID volume, the command might report that volume creation has failed.

For example:. If you retype the sas2ircu command at the Oracle Solaris prompt, the command will fail. The sas2ircu command will state that the wrong number of disks have been provided, since they had already been committed to a volume. After the initial failure of the sas2ircu command, other disk utility commands, such as formatmight show disk members of the volume marked as drive not available.

The format command might appear to hang and will require that you type Ctrl-C to abort the command. Alternatively, you can use one of the other available methods to create the volume, instead of the sas2ircu command. Create a volume under Oracle Solaris with the raidconfig command.

The Oracle Hardware Management Pack includes the raidconfig command. You can read and download documentation for the version of Oracle Hardware Management Pack you are using at:. Exit Print View. Search Scope:. This Document Entire Library.

Version All rights reserved. You are about to create an IR volume. For example: format Searching for disks Legal Notices.It replaces the Fusion MPT cards. Even it's not full of features theses card appear to work fine and are supported by an opensource Linux driver. A proprietary monitoring tool is available but it nearly offers no management features. Some seem to be required dependencies. Others look like being real drivers but we haven't used them yet.

There's no opensource tool for theses new cards. However, LSI provides a command line management tool named sas2ircu.

LSI HBA 9211-8i PCIE Sas Controller for home Server - Home Server Build Part 2

Management features are really basicso it's better to use it as a reporting tool only. It includes a python wrapper around sas2ircu command and an initscript which daemonize the launch of the wrapper. It also handles failure detection and report it by mail and syslog.

RH2288H V3 系统侧执行RAID卡命令有报错

It also handle unexpected output changes and reminders until the status is fine again. Any error will turn exit code to 2, which means critical error in Nagios. I haven't been able to really test it yet, so please use it carefully and contact me if you have a server on which you are able to do some testing plug disks, unplug, create hotspare You need to make sure SCSI generic device driver is loaded and will be loaded at boot.

On Debian based system, simply run:. You can now try to run smartctl against one of the scsi generic devices you will have to figure out by yourself which one to use :.

Powered by Trac 1. Login Preferences GitHub.

React fill pdf form

Wiki Search. Card information 2. Linux kernel drivers 3. Management and reporting tools 3. T and such 4.What's new New posts New resources New profile posts Latest activity. Resources Latest reviews Search resources. Members Current visitors New profile posts Search profile posts. Search Everywhere Threads This forum This thread. Search titles only. Search Advanced search….

Everywhere Threads This forum This thread. Search Advanced…. Log in. Thread starter nthu Start date Dec 26, Tags esxi 6. JavaScript is disabled.

Sp60 air pistol india

For a better experience, please enable JavaScript in your browser before proceeding. Feb 3, 1, 83 San Antonio, TX. Hope you all had good holidays! These are internal but based on the C0 stepping of and could not be flashed to i as discussed in the Intel Xeon e pricing thread. I've also experienced VM file corruption on one of the drives also. Using Intel OEM cables so hopefully that is not contributing factor. I guess I can first update the flash to Suspect missing LSI modules.

sas2ircu mptlib2 error 1

See attached command output and screen clip for more details. Nov 10, 1, 83 Canada. Dunno about your exact issue, so probably not much help, but my guess is that it's most likely either twitchy firmware on those cards and or perhaps vib related.

Have you tested the cards with the stock Intel firmware under ESXi?

Sas2ircu Linux

Updated the FW to make both cards to match This topic describes how to rectify the fault that the RH V3 automatically shuts down. Source of the Problem. If yes, no further action is required. If no, go to Step 2. If yes, go to Step 3. Contact Huawei technical support for help. If no, no further action is required. An RH V3 server was powered off for protection after a power alarm was generated, and could not be powered on.

Drop alarm. The following figure shows how a PwrOk Sig. Drop alarm is generated. This problem is caused by the mainboard fault. You are advised to apply for a spare mainboard for replacement. Drop alarm, do not power off and then power on the server. Otherwise, a short circuit may occur due to secondary damage of the mainboard. The same symptom appears on other servers with the same configuration.

The legacy PXE cannot access the high-order address space. Disable the above 4G decoding function. On the displayed screen, set Above 4G to Disable.

Help needed VMware ESXi 6.5 issues with HBA

In this way, PXE is available in legacy mode. Cause analysis:. The voltages of the CPUs in the same server are inconsistent. As a result, the server fails to initialize the CPUs. Analyze the alarm based on other events alarms. Key process.

Possible Causes. Verification: The UCE alarm is cleared and the server works properly. PwrOk sig. Drop is reported when the RH V3 is powered on again after it reports the CPU overtemperature alarm thermal trip during a power-on. The CPU temperature increases continuously. The voltage is controlled by the CPU. If the CPU is abnormal, the vrd voltage may be abnormal. Therefore, the CPU may encounter an internal working exception for example, the power supply is short-circuitedcausing CPU overtemperature.

If yes, go to the next step. If no, replace the mainboard. Otherwise, replace the mainboard.Experts Exchange always has the answer, or at the least points me in the correct direction! It is like having another employee that is extremely experienced. Being involved with EE helped me to grow personally and professionally. We've partnered with two important charities to provide clean water and computer science education to those who need it most.

Connect with Certified Experts to gain insight and support on specific technology challenges including:. Experts Exchange is the only place where you can interact directly with leading experts in the technology field.

Lgsm rust commands

Become a member today and access the collective knowledge of thousands of technology experts. View solution. View Solution. Why EE? Courses Ask. Get Access.

Log In. Web Dev. We help IT Professionals succeed at work. Last Modified: Tried a few solutions but they did not work, eg. Start Free Trial. View Solution Only. Seth Simmons Lead Systems Administrator.

sas2ircu mptlib2 error 1

Commented: Author Commented: Top Expert This award recognizes someone who has achieved high tech and professional accomplishments as an expert in a specific topic.Sas2ircu Linux. Storage, Volumes, Volume Manager. During these stress tests and benchmarks, StressLinux monitors the health of the hardware. Bryan Vyhmeister's blog post about flashing IT firmware; mycusthelp.

For such reason, I request this snap to be allowed as non-confined. However, remote management of ESXi 5. These commands still work on the hardware even when it is in IT Initiator Target mode.

The following display targets are supported under linux: X11 and OpenGL. This is for. When you use SAS2IRCU commands, the program sends results to the environment through the program status value that it returns when it exits. Some linux tools are available on a CD included with the controller. Install the sas2ircu somewhere of use, and then run it similar to this:. To install: Download the sas3ircu command. Build with OpenSSL instead of gnutsl build with gnutls don't work with latest mcabber.

During the installation of Red Hat Linux 4. Creates Ohai hint files, which are consumed by Ohai plugins in order to determine if they should run or not. If I get a chance to do it, I will and. I'll try and update this thread later this evening but, worst case, I'll update the thread once the rebuild is complete. I've update to the most recent firmware as part of troubleshooting but they haven't released new firmware for that in years. When I built this array I used sas2ircu to map out the serial numbers of the drives to the slot number on the backplane — this is critical to successfully pulling the correct disk:.

I'm attaching its output for info running the command. Don't confuse yourself with drive characteristics. I'm running Centos 7. Add extra documentation API, Javadoc, etc. Uramono Columbian blogger who has about 20 blog that were created in the past 10 years.

sas2ircu mptlib2 error 1

Download sas2ircu Output from the sas2ircu utility - display devices of adapter 0 - sas2ircu 0 display. Gentoo Packages Database. Assuming you connected the cables between the LSI and the backplane in proper sequence sas2ircu will tell you the slot number the drives are plugged into on the LSI controller.

It is a minimally interactive program that you can execute from a command-line prompt or a shell script. Version In most cases where LSI cards are in use, you will want sas2ircu for Solaris. It includes a python wrapper around sas2ircu command and an initscript which daemonize the launch of the wrapper.

Readers should have a basic understanding about linux. The first, and my preference, is sas2ircu. Hyper-fast 10Gbps Networking — Enjoy up to 10X-faster data-transfer speeds for bandwidth-demanding tasks. Here's my issue: Every time I've rebooted the Linux guest, the changes the status to "degraded" and proceeds to resync the RAID1 of the 1TB drives - which takes about 2 days.

Stack Exchange Network.